{"id":5128,"date":"2025-10-22T09:38:22","date_gmt":"2025-10-22T08:38:22","guid":{"rendered":"https:\/\/www.springboard.pro\/?p=5128"},"modified":"2026-08-31T21:21:04","modified_gmt":"2026-08-31T21:21:04","slug":"blef-force-modelling-method","status":"publish","type":"blog","link":"https:\/\/www.sanner-group.com\/insights\/blog\/blef-force-modelling-method\/","title":{"rendered":"Accelerating Time to Market for New Injection Devices Using a Novel Force-Modeling Method and Software"},"content":{"rendered":"\n<section id=\"armstrong-block-editor-block_3bce2fa2cc03cc99bd4494adb9810389\" class=\"armstrong-block armstrong-block-editor\" >\n    <div class=\"container-fluid\">\n        <div class=\"row\">\n            <div class=\"col-lg-12\">\n                                <p>New injection devices are being asked to deliver larger volume injections, with higher viscosity formulations, and with increasing expectations of users on device aesthetics, simplicity, and quality. All injection devices risk finding that they fail to perform adequately when challenged with components, volumes, and viscosities at the upper end of their tolerances. The risk of failure is present when developing devices for biosimilars and generics too.<\/p>\n<p>Therefore, it is becoming ever more important to predict a device\u2019s behavior early in the development, and to predict the effect of shelf life aging. However, with increased drug viscosity and volume comes more complex force requirements, and basic methods of predicting plunger forces are not sufficiently capable.<\/p>\n<p>The nightmare scenario is that an injection device is designed, taken through tooling and automation, and design verification testing, and then found to fail its performance requirements after shelf life.<\/p>\n<p>Here we describe a new method and enabling software that we developed to enable engineers to translate basic syringe test data into injection device performance, and to work backwards from device performance after shelf life to the maximum forces they can allow in a syringe test. This can be done early in development to avoid failures late in the program.<\/p>\n<h2>Why use break-loose extrusion force data?<\/h2>\n<p>Break-loose and extrusion force (BLEF) tests are a common way to characterize prefilled syringes (with plungers). In a BLEF test a machine called a tensometer drives a plunger at constant-speed and measures the (varying) force as the plunger moves down the syringe.<\/p>\n<p>The force-distance chart created in a BLEF test shows useful information: the initial break-loose force of the stationary plunger; the extrusion force (which comprises of dynamic plunger-syringe friction, and the drug formulation\u2019s back pressure); and a small dip in force indicative of an air bubble expelled after drug delivery.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"full-width-image\" src=\"https:\/\/www.sanner-group.com\/wp-content\/uploads\/2025\/10\/Plunger-force-vs-position-graph-in-BLEF-test.png.jpg\" sizes=\"auto, (max-width: 1378px) 100vw, 1378px\" srcset=\"https:\/\/www.sanner-group.com\/wp-content\/uploads\/2025\/10\/Plunger-force-vs-position-graph-in-BLEF-test.png.jpg 1378w, https:\/\/www.sanner-group.com\/wp-content\/uploads\/2025\/10\/Plunger-force-vs-position-graph-in-BLEF-test.png-300x136.jpg 300w, https:\/\/www.sanner-group.com\/wp-content\/uploads\/2025\/10\/Plunger-force-vs-position-graph-in-BLEF-test.png-1024x463.jpg 1024w, https:\/\/www.sanner-group.com\/wp-content\/uploads\/2025\/10\/Plunger-force-vs-position-graph-in-BLEF-test.png-768x347.jpg 768w\" alt=\"\" width=\"1378\" height=\"623\" \/><\/p>\n<p>ISO 11040-8 mandates that such tests use the complete, final system \u201cas intended for use\u201d and that the designer considers how forces vary with aging and environmental factors. BLEF testing is valuable for characterizing relationships between forces and plunger speed, syringe or needle dimensions, and fluid properties. However, it cannot be used to accurately predict injection times in an injection device because it does not reflect dynamic injection behavior. Therefore, we need a tool that can use common BLEF test data to provide accurate predictions for injection device performance.<\/p>\n<p>To address this, Sanner has co-developed advanced modeling software with Pfizer\u2019s Devices Centre of Excellence. It allows device developers to easily forecast injection times, anticipate variation due to aging, and set meaningful specifications early in the development process. The software can bridge the gap between constant-speed BLEF data and dynamic injection device performance without the need for guesswork, reducing the number of slow and costly prototype testing cycles and rework.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"full-width-image\" src=\"https:\/\/www.sanner-group.com\/wp-content\/uploads\/2025\/10\/Process-for-BLEF-test.png.jpg\" sizes=\"auto, (max-width: 940px) 100vw, 940px\" srcset=\"https:\/\/www.sanner-group.com\/wp-content\/uploads\/2025\/10\/Process-for-BLEF-test.png.jpg 940w, https:\/\/www.sanner-group.com\/wp-content\/uploads\/2025\/10\/Process-for-BLEF-test.png-300x34.jpg 300w, https:\/\/www.sanner-group.com\/wp-content\/uploads\/2025\/10\/Process-for-BLEF-test.png-768x87.jpg 768w\" alt=\"\" width=\"940\" height=\"107\" \/><\/p>\n<h2>A new model and software for device performance<\/h2>\n<p>Software users simply upload their own BLEF data into the software and in a few steps can generate:<\/p>\n<ol>\n<li>A predicted distribution of injection times for their specified device;<\/li>\n<li>Maximum extrusion force requirement predictions; and<\/li>\n<li>A report for their Design History File.<\/li>\n<\/ol>\n<p>The model behind the software uses a time-stepped approach to break down an injection into discrete, calculable steps. Each loop begins with a known plunger position, which relates to the device\u2019s spring length. From this the spring force is known and is assumed approximately equal to the current extrusion force.<\/p>\n<p>Using relationships from the user\u2019s BLEF data for the modelled syringe, the extrusion force is used to work back to the plunger speed and internal syringe pressure. By calculating the Hagen-Poiseuille equation across the needle, the pressure is related to the velocity of fluid ejected.<\/p>\n<p>The plunger movement can then be calculated due to the reduction in injection volume and considering the change in any air bubble volume due to pressure changes \u2013 this is a step which is important to capture but complex and challenging to do through other predictive methods. This loop is repeated until all the volume has been delivered, and the total time elapsed gives the device injection time.<\/p>\n<p>This software uses the Monte Carlo method to sample the random variation of all input parameters which include:<\/p>\n<ol>\n<li>User-specified tolerances on input parameters; and<\/li>\n<li>The variance of real BLEF data.<\/li>\n<\/ol>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"full-width-image\" src=\"https:\/\/www.sanner-group.com\/wp-content\/uploads\/2025\/10\/BLEF-test-workflow.jpg\" sizes=\"auto, (max-width: 2029px) 100vw, 2029px\" srcset=\"https:\/\/www.sanner-group.com\/wp-content\/uploads\/2025\/10\/BLEF-test-workflow.jpg 2029w, https:\/\/www.sanner-group.com\/wp-content\/uploads\/2025\/10\/BLEF-test-workflow-286x300.jpg 286w, https:\/\/www.sanner-group.com\/wp-content\/uploads\/2025\/10\/BLEF-test-workflow-976x1024.jpg 976w, https:\/\/www.sanner-group.com\/wp-content\/uploads\/2025\/10\/BLEF-test-workflow-768x806.jpg 768w, https:\/\/www.sanner-group.com\/wp-content\/uploads\/2025\/10\/BLEF-test-workflow-1464x1536.jpg 1464w, https:\/\/www.sanner-group.com\/wp-content\/uploads\/2025\/10\/BLEF-test-workflow-1952x2048.jpg 1952w\" alt=\"\" width=\"2029\" height=\"2129\" \/><\/p>\n<h2>Coping with device aging<\/h2>\n<p>Various factors lead to device performance degradation over time, most notably desiliconization of the syringe which leads to increased plunger-syringe friction. Device performance after shelf-life is more likely to fail requirements such as injection time than on the day the device was manufactured. This is bad news for development projects because issues might not be discovered until years into a program.<\/p>\n<p>Therefore, we used newly-siliconized and desiliconized syringes as best and worst cases for plunger-syringe friction and used desiliconization as a surrogate for aging. We can say that syringes effectively move away from newly-siliconized performance as they age. Depending on their aging properties, most will never get near to fully desiliconized.<\/p>\n<p>We have extended the software described above to establish ageing trends using a small number of single-speed BLEF tests on aged syringes. This effect is modelled by increasing theoretical break loose and extrusion forces until devices would stall or breach injection time limits. This gives the worst-case syringes that can be allowed. Then, by back-calculating from end-of-shelf-life performance to initial conditions, the method can define a maximum allowable BLEF result at time zero. This allows engineers to specify the maximum forces allowed on a BLEF test at time zero and still be confident that the injection device would perform after shelf life.<\/p>\n<h2>Summary<\/h2>\n<p>If injection time performance is not properly predicted (including predictions for after shelf-life), a device program risks substantial cost and time overruns. The cost and time come from having to implement time-consuming and expensive component modifications and reverification testing.<\/p>\n<p>Instead, we can use the new model described in this article to change the physical build-and-test loop into a mathematical model, which specifies acceptable force limits for easy BLEF tests early in the program. These predictive tools will become increasingly essential for efficient and reliable device development as drug delivery systems evolve to accommodate more demanding formulations. Our modeling software offers a practical solution by translating BLEF test data into more accurate forecasts of injection performance over a device\u2019s lifespan.<\/p>\n<h4>Authors<\/h4>\n<p>Sanner:<\/p>\n<ul>\n<li>Matthew Latham, Consultant Engineer<\/li>\n<li>Elena Guss Tarazona, Consultant Engineer<\/li>\n<li>Bradley Sawyer, Consultant Engineer<\/li>\n<\/ul>\n<p>Pfizer:<\/p>\n<ul>\n<li>Jay Sayed, Principal Scientist<\/li>\n<li>Charlie Bowen, Design Engineer<\/li>\n<li>Harriet Field, Laboratory Scientist Apprentice<\/li>\n<\/ul>\n<p>Featured in <a href=\"https:\/\/www.ondrugdelivery.com\/accelerating-time-to-market-for-new-injection-devices-using-a-novel-force-modelling-method-and-software\/\">On Drug Delivery<\/a>; edited to appear on our site with American writing conventions<\/p>\n            <\/div>\n        <\/div>\n    <\/div>\n<\/section>","protected":false},"featured_media":5771,"template":"","blog_category":[75],"class_list":["post-5128","blog","type-blog","status-publish","has-post-thumbnail","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.6 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Accelerating Time to Market for New Injection Devices Using a Novel Force-Modeling Method and Software - Sanner Group<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.sanner-group.com\/fr\/insights\/blog\/blef-force-modelling-method\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Accelerating Time to Market for New Injection Devices Using a Novel Force-Modeling Method and Software - Sanner Group\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.sanner-group.com\/insights\/blog\/blef-force-modelling-method\/\" \/>\n<meta property=\"og:site_name\" content=\"Sanner Group\" \/>\n<meta property=\"article:modified_time\" content=\"2026-08-31T21:21:04+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.sanner-group.com\/wp-content\/uploads\/2025\/10\/PC2-300DPI-1024x719.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1024\" \/>\n\t<meta property=\"og:image:height\" content=\"719\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.sanner-group.com\\\/insights\\\/blog\\\/blef-force-modelling-method\\\/\",\"url\":\"https:\\\/\\\/www.sanner-group.com\\\/insights\\\/blog\\\/blef-force-modelling-method\\\/\",\"name\":\"Accelerating Time to Market for New Injection Devices Using a Novel Force-Modeling Method and Software - Sanner Group\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.sanner-group.com\\\/fr\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.sanner-group.com\\\/insights\\\/blog\\\/blef-force-modelling-method\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.sanner-group.com\\\/insights\\\/blog\\\/blef-force-modelling-method\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.sanner-group.com\\\/wp-content\\\/uploads\\\/2025\\\/10\\\/PC2-300DPI.png\",\"datePublished\":\"2025-10-22T08:38:22+00:00\",\"dateModified\":\"2026-08-31T21:21:04+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.sanner-group.com\\\/insights\\\/blog\\\/blef-force-modelling-method\\\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.sanner-group.com\\\/insights\\\/blog\\\/blef-force-modelling-method\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/www.sanner-group.com\\\/insights\\\/blog\\\/blef-force-modelling-method\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.sanner-group.com\\\/wp-content\\\/uploads\\\/2025\\\/10\\\/PC2-300DPI.png\",\"contentUrl\":\"https:\\\/\\\/www.sanner-group.com\\\/wp-content\\\/uploads\\\/2025\\\/10\\\/PC2-300DPI.png\",\"width\":2561,\"height\":1799,\"caption\":\"Analysis of BLEF data by an engineer\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.sanner-group.com\\\/insights\\\/blog\\\/blef-force-modelling-method\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.sanner-group.com\\\/fr\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Accelerating Time to Market for New Injection Devices Using a Novel Force-Modeling Method and Software\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.sanner-group.com\\\/fr\\\/#website\",\"url\":\"https:\\\/\\\/www.sanner-group.com\\\/fr\\\/\",\"name\":\"Sanner Group\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.sanner-group.com\\\/fr\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Accelerating Time to Market for New Injection Devices Using a Novel Force-Modeling Method and Software - Sanner Group","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.sanner-group.com\/fr\/insights\/blog\/blef-force-modelling-method\/","og_locale":"fr_FR","og_type":"article","og_title":"Accelerating Time to Market for New Injection Devices Using a Novel Force-Modeling Method and Software - Sanner Group","og_url":"https:\/\/www.sanner-group.com\/insights\/blog\/blef-force-modelling-method\/","og_site_name":"Sanner Group","article_modified_time":"2026-08-31T21:21:04+00:00","og_image":[{"width":1024,"height":719,"url":"https:\/\/www.sanner-group.com\/wp-content\/uploads\/2025\/10\/PC2-300DPI-1024x719.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Dur\u00e9e de lecture estim\u00e9e":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.sanner-group.com\/insights\/blog\/blef-force-modelling-method\/","url":"https:\/\/www.sanner-group.com\/insights\/blog\/blef-force-modelling-method\/","name":"Accelerating Time to Market for New Injection Devices Using a Novel Force-Modeling Method and Software - Sanner Group","isPartOf":{"@id":"https:\/\/www.sanner-group.com\/fr\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.sanner-group.com\/insights\/blog\/blef-force-modelling-method\/#primaryimage"},"image":{"@id":"https:\/\/www.sanner-group.com\/insights\/blog\/blef-force-modelling-method\/#primaryimage"},"thumbnailUrl":"https:\/\/www.sanner-group.com\/wp-content\/uploads\/2025\/10\/PC2-300DPI.png","datePublished":"2025-10-22T08:38:22+00:00","dateModified":"2026-08-31T21:21:04+00:00","breadcrumb":{"@id":"https:\/\/www.sanner-group.com\/insights\/blog\/blef-force-modelling-method\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.sanner-group.com\/insights\/blog\/blef-force-modelling-method\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.sanner-group.com\/insights\/blog\/blef-force-modelling-method\/#primaryimage","url":"https:\/\/www.sanner-group.com\/wp-content\/uploads\/2025\/10\/PC2-300DPI.png","contentUrl":"https:\/\/www.sanner-group.com\/wp-content\/uploads\/2025\/10\/PC2-300DPI.png","width":2561,"height":1799,"caption":"Analysis of BLEF data by an engineer"},{"@type":"BreadcrumbList","@id":"https:\/\/www.sanner-group.com\/insights\/blog\/blef-force-modelling-method\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.sanner-group.com\/fr\/"},{"@type":"ListItem","position":2,"name":"Accelerating Time to Market for New Injection Devices Using a Novel Force-Modeling Method and Software"}]},{"@type":"WebSite","@id":"https:\/\/www.sanner-group.com\/fr\/#website","url":"https:\/\/www.sanner-group.com\/fr\/","name":"Sanner Group","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.sanner-group.com\/fr\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"}]}},"permalink_manager":null,"_links":{"self":[{"href":"https:\/\/www.sanner-group.com\/fr\/wp-json\/wp\/v2\/blog\/5128","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.sanner-group.com\/fr\/wp-json\/wp\/v2\/blog"}],"about":[{"href":"https:\/\/www.sanner-group.com\/fr\/wp-json\/wp\/v2\/types\/blog"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.sanner-group.com\/fr\/wp-json\/wp\/v2\/media\/5771"}],"wp:attachment":[{"href":"https:\/\/www.sanner-group.com\/fr\/wp-json\/wp\/v2\/media?parent=5128"}],"wp:term":[{"taxonomy":"blog_category","embeddable":true,"href":"https:\/\/www.sanner-group.com\/fr\/wp-json\/wp\/v2\/blog_category?post=5128"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}