{"id":5971,"date":"2024-01-23T10:38:01","date_gmt":"2024-01-23T10:38:01","guid":{"rendered":"https:\/\/www.springboard.pro\/?p=4620"},"modified":"2026-09-01T19:25:39","modified_gmt":"2026-09-01T19:25:39","slug":"liquid-silicone-rubber-for-medical-device-design","status":"publish","type":"blog","link":"https:\/\/www.sanner-group.com\/insights\/blog\/liquid-silicone-rubber-for-medical-device-design\/","title":{"rendered":"From Concept to Cure: Mastering Liquid Silicone Rubber for Medical Device Design"},"content":{"rendered":"\n<section id=\"armstrong-block-editor-block_5ffc9c7452871c1e713fcfd92666855d\" class=\"armstrong-block armstrong-block-editor\" >\n    <div class=\"container-fluid\">\n        <div class=\"row\">\n            <div class=\"col-lg-12\">\n                                <p>Liquid silicone rubber (LSR) is frequently used in implants due to its bio-inert nature, meaning that it has a very low propensity to initiate a response or interaction when introduced to biological tissue.(<span class=\"ordinal\">1)<\/span>\u00a0It is also a common choice in non-implantable drug delivery devices, as it lowers development risk when performing the relevant biocompatibility tests recommended in ISO 10993 and US Pharmacopeia Class VI. This property also makes LSR suitable for the drug flow path, where reliable performance in extractables and leachables testing is critical. For example,\u00a0<a href=\"https:\/\/www.ondrugdelivery.com\/companies\/raumedic-ag\/\">Raumedic<\/a> provides a range of customized silicone syringe plungers with this as one of its unique selling points<span class=\"ordinal\">.(2)<\/span><\/p>\n<p><strong><span class=\"gold\">More than meets the skin<\/span><\/strong><\/p>\n<p>Compared with other elastomers, silicone rubbers have the best compression set performance. Typical values are around 10%\u201320%,<span class=\"ordinal\">3<\/span>\u00a0compared with other elastomers with compression sets of 40%\u201370%.<span class=\"ordinal\">4<\/span>\u00a0This makes LSR a more robust choice for seals in devices with a long service and\/or shelf life. When comparing different LSR grades, it is important to keep in mind that there are differing standards for compression set testing that can affect the number quoted on the datasheet. Different additives, and even manufacturing conditions, can further improve or impair this property \u2013 for example, self-adhesive grades can exhibit a much higher compression set of 40%\u201360%.<span class=\"ordinal\">5<\/span><\/p>\n<p>All rubbers typically exhibit high friction, with coefficients of around 0.5\u20131.0. However, LSR is likely to be a suitable choice when compared with its peers if a complex dynamic seal is required while avoiding any additional coating processes. Harder silicones with a higher durometer score typically exhibit a lower coefficient of friction, however, their decreased compliance results in a smaller tolerance window for effective sealing and friction forces. The surface finish of both sealing surfaces is also extremely important, where more polished surfaces can increase the coefficient significantly. Finally, the friction performance of similar grades from different manufacturers can vary, so it is advisable to carry out functional testing with a range of options to maximize the chance of design success. Most LSR suppliers provide a range of low-friction LSR grades, however the coefficients of friction are usually not quoted. It is therefore prudent to be skeptical of any marketing claims, especially if grades have contradictory attributes such as \u201clow friction\u201d and \u201cself-adhesive\u201d.<\/p>\n<p>Two-shot (2K) LSR over molding is a common operation in the world of silicone. The most advanced high-volume systems use a rotating table with parallel substrate and LSR injections to increase throughput. Automated pick and place systems are also used at lower volumes and, at the prototyping stage, the molder will do this manually. Part design requires some care, where any high-contact-force dynamic seals may also require mechanical interlocking features to back up any chemical adhesion that comes from using a primer or self-adhesive grade. Typical materials to pair with LSR include polybutylene terephthalate (PBT), polyamide (PA), polycarbonate (PC) and polyethylene terephthalate (PET).<\/p>\n<p>Despite its propensity to crosslink and slightly harden, platinum-cured LSR is compatible with gamma or X-ray sterilization. At industry-standard radiation doses of 25 kGy, Gautriaud et al noted an increase of the shore hardness of Wacker\u2019s (Munich, Germany) Elastosil<span class=\"ordinal\">\u00ae<\/span>\u00a03003\/50 by four points, as seen in Figure 1.<span class=\"ordinal\">6,7<\/span> If this increase is accounted for in the design phase, it is possible to employ this method for end-of-line sterilization to reach any surfaces that are sealed away.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"full-width-image\" src=\"https:\/\/www.sanner-group.com\/wp-content\/uploads\/2024\/01\/Figure-1.png\" sizes=\"auto, (max-width: 662px) 100vw, 662px\" srcset=\"https:\/\/www.sanner-group.com\/wp-content\/uploads\/2024\/01\/Figure-1.png 662w, https:\/\/www.sanner-group.com\/wp-content\/uploads\/2024\/01\/Figure-1-300x221.png 300w\" alt=\"\" width=\"662\" height=\"487\" \/><\/p>\n<p><em>Figure 1: Effect of gamma radiation on durometer hardness of silicone rubbers.(<span class=\"ordinal\">7)<\/span><\/em><\/p>\n<p><strong><span class=\"gold\">The LSR process is a bit different<\/span><\/strong><\/p>\n<p>LSR is typically supplied as A and B components in pails, mixed in a 50:50 ratio at room temperature and then pushed into a hot mold tool. Tool temperatures of around 200\u00b0C allow curing times in the order of seconds. A longer cure time at lower temperatures may be used at the prototyping stage without a drop in part quality.<\/p>\n<p>Note that the properties, such as the viscosity, of the mixed A and B components can vary significantly between different material grades, which can end up causing unforeseen headaches for a molder trying to use the same equipment over a range of grades. Additionally, the flowability of the mixed components can affect the expected tolerance ranges of any surfaces.<\/p>\n<p>The tolerance of an LSR part is highly dependent on the manufacturer of the tool and the design of the part. Typically, shrink rates are high but consistent throughout the part. As long as the LSR is unconstrained during shrinking, a quality tool can produce LSR parts accurately. Walls as thin as 0.25 mm are possible, but the flipside of this is that LSR will flash very easily. If possible, move any parting lines and ejector pins away from sealing surfaces to minimize the chance of leakage.<\/p>\n<div id=\"attachment_34399\" class=\"wp-caption alignright\"><\/div>\n<p>Even large contract manufacturers are unlikely to have professional LSR molding machines, leaving the practice to specialists like Trelleborg (Trelleborg, Sweden) or Raumedic. However, with the right partner, accurate prototypes can be made using a pump and heated tool that is opened and shut manually. An example of this set-up is shown in Figure 2.<\/p>\n<p>Manufacturers only familiar with mechanical probe-based co-ordinate measuring machines (CMMs) may also struggle to measure the part. A brief summary of measurement methods for LSR can be found in Table 1.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"full-width-image\" src=\"https:\/\/www.sanner-group.com\/wp-content\/uploads\/2024\/01\/Figure-2-scaled-1.jpg\" sizes=\"auto, (max-width: 2560px) 100vw, 2560px\" srcset=\"https:\/\/www.sanner-group.com\/wp-content\/uploads\/2024\/01\/Figure-2-scaled-1.jpg 2560w, https:\/\/www.sanner-group.com\/wp-content\/uploads\/2024\/01\/Figure-2-scaled-1-300x263.jpg 300w, https:\/\/www.sanner-group.com\/wp-content\/uploads\/2024\/01\/Figure-2-scaled-1-1024x896.jpg 1024w, https:\/\/www.sanner-group.com\/wp-content\/uploads\/2024\/01\/Figure-2-scaled-1-768x672.jpg 768w, https:\/\/www.sanner-group.com\/wp-content\/uploads\/2024\/01\/Figure-2-scaled-1-1536x1344.jpg 1536w, https:\/\/www.sanner-group.com\/wp-content\/uploads\/2024\/01\/Figure-2-scaled-1-2048x1792.jpg 2048w\" alt=\"\" width=\"2560\" height=\"2240\" \/><\/p>\n<p><em>Figure 2: Manual LSR mold tool for low-volume prototype components.<\/em><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"full-width-image\" src=\"https:\/\/www.sanner-group.com\/wp-content\/uploads\/2024\/01\/Table-1.png\" sizes=\"auto, (max-width: 1815px) 100vw, 1815px\" srcset=\"https:\/\/www.sanner-group.com\/wp-content\/uploads\/2024\/01\/Table-1.png 1815w, https:\/\/www.sanner-group.com\/wp-content\/uploads\/2024\/01\/Table-1-300x202.png 300w, https:\/\/www.sanner-group.com\/wp-content\/uploads\/2024\/01\/Table-1-1024x689.png 1024w, https:\/\/www.sanner-group.com\/wp-content\/uploads\/2024\/01\/Table-1-768x517.png 768w, https:\/\/www.sanner-group.com\/wp-content\/uploads\/2024\/01\/Table-1-1536x1033.png 1536w\" alt=\"\" width=\"1815\" height=\"1221\" \/><\/p>\n<p><em>Table 1: Measurement methods for LSR.<\/em><\/p>\n<p><strong><span class=\"gold\">Hyperelastic finite element analysis<\/span><\/strong><\/p>\n<p>Finite element analysis (FEA) of rubber components is a common point of discussion, due to the difficulty and amount of up-front investment required to prototype them. For medical device engineers, an FEA model also provides the ability to try a variety of dimensions across the tolerance ranges and map the contact pressures along the seal. This helps to build confidence that the design will be robust to sigma level six or \u201cfive nines\u201d.<\/p>\n<p>A \u201cgold standard\u201d FEA model would start with a set of the following material tests<span class=\"ordinal\">,8<\/span>\u00a0ranked in order of importance:<\/p>\n<ol>\n<li>An equibiaxial tension test \u2013 as LSR is nearly incompressible, this creates a loading state equivalent to pure compression, without the friction that would be impossible to avoid with a simple compression test<\/li>\n<li>A planar tension test (pure shear) \u2013 also due to the LSR being nearly incompressible, using a wide sample creates a state of pure shear at a 45\u00b0 angle.<\/li>\n<li>A simple tension test.<\/li>\n<\/ol>\n<p>The results of these tests can then be curve-fitted against different material models, such as Mooney-Rivlin, Neo-Hookean, Arruda-Boyce, Ogden or Yeoh. The curve with the best fit is then selected for use with the final FEA model.<\/p>\n<p>The problem with the \u201cgold standard\u201d approach is that engineers are unlikely to know exactly which material grade is the most preferable at the outset. Also, material suppliers are unlikely to share data for niche material test methods, so performing these tests requires extra investment. As a first pass, it is possible to use a set of Mooney-Rivlin parameters for hyperelastic materials shared across the FEA community,<span class=\"ordinal\">9,10<\/span> which have been found to be good enough when trying different concept designs and material shore hardnesses. If there is still a desire to revisit the FEA for design optimization before tooling, the material tests can be conducted with the selected grade to confirm the result and conduct any optimization tweaks.<\/p>\n<p>A demonstration of a hyperelastic FEA model is shown in Figures 3 and 4, where Figure 3 shows the assembly of two components which are sealed by an LSR O-ring, and Figure 4 shows the effect of pressurization from the top side. The surface stress at the sealing faces is equivalent to the contact pressure, which can be used to determine the integrity of the seal. Conducting hyperelastic FEA requires a skilled operator with an understanding of common pitfalls in model set-up \u2013 for example, meshing producing artefacts, such as hourglassing, during the solve.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"full-width-image\" src=\"https:\/\/www.sanner-group.com\/wp-content\/uploads\/2024\/01\/Figure-3-freeze.png\" sizes=\"auto, (max-width: 2000px) 100vw, 2000px\" srcset=\"https:\/\/www.sanner-group.com\/wp-content\/uploads\/2024\/01\/Figure-3-freeze.png 2000w, https:\/\/www.sanner-group.com\/wp-content\/uploads\/2024\/01\/Figure-3-freeze-300x223.png 300w, https:\/\/www.sanner-group.com\/wp-content\/uploads\/2024\/01\/Figure-3-freeze-1024x761.png 1024w, https:\/\/www.sanner-group.com\/wp-content\/uploads\/2024\/01\/Figure-3-freeze-768x571.png 768w, https:\/\/www.sanner-group.com\/wp-content\/uploads\/2024\/01\/Figure-3-freeze-1536x1141.png 1536w\" alt=\"\" width=\"2000\" height=\"1486\" \/><\/p>\n<p><em>Figure 3: Hyperelastic FEA model of the assembly of two components and an LSR O-ring.<\/em><\/p>\n<p><strong><span class=\"gold\">Gauging real-world performance\u00a0<\/span><\/strong><\/p>\n<p>A full suite of mechanical testing equipment is required to test LSR components, some examples of which are shown in Figure 5. Force testers are extremely useful for running long-term seal compression tests in parallel. A torque tester can be indispensable for the testing of dynamic rubber seals driven by a motor or clock spring.<\/p>\n<p>For medical device designers, any statistical analysis must be robust against the tough requirements set by regulators. This is especially relevant when producing components that seal, where tolerance stacks must be tightly controlled to ensure that there is adequate contact pressure for effective fluid retention.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"full-width-image\" src=\"https:\/\/www.sanner-group.com\/wp-content\/uploads\/2024\/01\/Figure-5-scaled-1.jpg\" sizes=\"auto, (max-width: 2560px) 100vw, 2560px\" srcset=\"https:\/\/www.sanner-group.com\/wp-content\/uploads\/2024\/01\/Figure-5-scaled-1.jpg 2560w, https:\/\/www.sanner-group.com\/wp-content\/uploads\/2024\/01\/Figure-5-scaled-1-300x225.jpg 300w, https:\/\/www.sanner-group.com\/wp-content\/uploads\/2024\/01\/Figure-5-scaled-1-1024x768.jpg 1024w, https:\/\/www.sanner-group.com\/wp-content\/uploads\/2024\/01\/Figure-5-scaled-1-768x576.jpg 768w, https:\/\/www.sanner-group.com\/wp-content\/uploads\/2024\/01\/Figure-5-scaled-1-1536x1152.jpg 1536w, https:\/\/www.sanner-group.com\/wp-content\/uploads\/2024\/01\/Figure-5-scaled-1-2048x1536.jpg 2048w\" alt=\"\" width=\"2560\" height=\"1920\" \/><\/p>\n<p><em>Figure 5: Mecmesin (Horsham, UK) force and torque testers.<\/em><\/p>\n<p><span class=\"gold\"><strong>Summary<\/strong><\/span><\/p>\n<p>In summary, LSR is a unique and useful material with excellent biocompatibility, compression set and friction properties without additives. The LSR molding process differs significantly from standard injection molding, and therefore requires a specific skillset and experience to design for, model and manufacture effectively.<\/p>\n<p>If you are working on a device with a critical compliant seal and need to make important design decisions, or if you have any general questions in this area, please feel free to <a href=\"https:\/\/www.sanner-group.com\/contact\">contact us to find out how we can help<\/a>.<\/p>\n<p>Written by Kamaal de Silva and featured in <a href=\"https:\/\/www.ondrugdelivery.com\/from-concept-to-cure-mastering-liquid-silicone-rubber-for-medical-device-design\/\">ONdrugDelivery<\/a>; edited to appear on our site with American writing conventions<\/p>\n<p><strong><span class=\"gold\">References<\/span><\/strong><\/p>\n<ol>\n<li><em>Rao HM et al, \u201cBioinert and Bioactive Materials \u2013 Narrative Review\u201d. J Pharm Negat, 2022, Vol 13(Special Issue 7), pp 2251\u20132255.<\/em><\/li>\n<li><em>\u201cCustomized silicone syringe plungers by Raumedic\u201d. Web page, Raumedic, accessed Jan 2024.<\/em><\/li>\n<li><em>Bayerl H, \u201cCompression Set of Silicone Elastomers\u201d. Int Ploym Sci Technol, 2009, Vol 36(8), pp 1\u20134.<\/em><\/li>\n<li><em>\u201cTPE with Optimised Compression Set\u201d. Web page, HEXPOL, accessed Jan 2024.<\/em><\/li>\n<li><em>\u201cELASTOSIL<span class=\"ordinal\">\u00ae<\/span>\u201d. Web page, Wacker, accessed Jan 2024.<\/em><\/li>\n<li><em>\u201cThe use of Ionising Radiation in the Manufacture of Medicinal Products\u201d. EMA Guidance, 1991.<\/em><\/li>\n<li><em>Gautriaud E et al, \u201cEffect of Sterilization on the Mechanical Properties of Silicone Rubbers\u201d. BioProcess International, Apr 2010.<\/em><\/li>\n<li><em>\u201cElastomer (hyperelastic) Characterization\u201d. Web page, Axel Physical Testing Services, accessed Jan 2024.<\/em><\/li>\n<li><em>Altidis P, Warner B, \u201cAnalyzing Hyperelastic Materials w\/ Some Practical Considerations\u201d. Presentation, Midwest ANSYS Users Group, May 2005.<\/em><\/li>\n<li><em>Lalo DF, Greco M, \u201cRubber bushing hyperelastic behavior based on shore hardness and uniaxial extension\u201d. 24th ABCM International Congress of Mechanical Engineering Conference, Dec 2017.<\/em><\/li>\n<\/ol>\n            <\/div>\n        <\/div>\n    <\/div>\n<\/section>","protected":false},"featured_media":5432,"template":"","blog_category":[],"class_list":["post-5971","blog","type-blog","status-publish","has-post-thumbnail","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.6 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>From Concept to Cure: Mastering Liquid Silicone Rubber for Medical Device Design - Sanner Group<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.sanner-group.com\/fr\/insights\/blog\/liquid-silicone-rubber-for-medical-device-design\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"From Concept to Cure: Mastering Liquid Silicone Rubber for Medical Device Design - Sanner Group\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.sanner-group.com\/insights\/blog\/liquid-silicone-rubber-for-medical-device-design\/\" \/>\n<meta property=\"og:site_name\" content=\"Sanner Group\" \/>\n<meta property=\"article:modified_time\" content=\"2026-09-01T19:25:39+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.sanner-group.com\/wp-content\/uploads\/2024\/01\/Figure-5-scaled-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"2560\" \/>\n\t<meta property=\"og:image:height\" content=\"1920\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.sanner-group.com\\\/insights\\\/blog\\\/liquid-silicone-rubber-for-medical-device-design\\\/\",\"url\":\"https:\\\/\\\/www.sanner-group.com\\\/insights\\\/blog\\\/liquid-silicone-rubber-for-medical-device-design\\\/\",\"name\":\"From Concept to Cure: Mastering Liquid Silicone Rubber for Medical Device Design - Sanner Group\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.sanner-group.com\\\/fr\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.sanner-group.com\\\/insights\\\/blog\\\/liquid-silicone-rubber-for-medical-device-design\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.sanner-group.com\\\/insights\\\/blog\\\/liquid-silicone-rubber-for-medical-device-design\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.sanner-group.com\\\/wp-content\\\/uploads\\\/2024\\\/01\\\/Figure-5-scaled-1.jpg\",\"datePublished\":\"2024-01-23T10:38:01+00:00\",\"dateModified\":\"2026-09-01T19:25:39+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.sanner-group.com\\\/insights\\\/blog\\\/liquid-silicone-rubber-for-medical-device-design\\\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.sanner-group.com\\\/insights\\\/blog\\\/liquid-silicone-rubber-for-medical-device-design\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/www.sanner-group.com\\\/insights\\\/blog\\\/liquid-silicone-rubber-for-medical-device-design\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.sanner-group.com\\\/wp-content\\\/uploads\\\/2024\\\/01\\\/Figure-5-scaled-1.jpg\",\"contentUrl\":\"https:\\\/\\\/www.sanner-group.com\\\/wp-content\\\/uploads\\\/2024\\\/01\\\/Figure-5-scaled-1.jpg\",\"width\":2560,\"height\":1920},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.sanner-group.com\\\/insights\\\/blog\\\/liquid-silicone-rubber-for-medical-device-design\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.sanner-group.com\\\/fr\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"From Concept to Cure: Mastering Liquid Silicone Rubber for Medical Device Design\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.sanner-group.com\\\/fr\\\/#website\",\"url\":\"https:\\\/\\\/www.sanner-group.com\\\/fr\\\/\",\"name\":\"Sanner Group\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.sanner-group.com\\\/fr\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"From Concept to Cure: Mastering Liquid Silicone Rubber for Medical Device Design - Sanner Group","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.sanner-group.com\/fr\/insights\/blog\/liquid-silicone-rubber-for-medical-device-design\/","og_locale":"fr_FR","og_type":"article","og_title":"From Concept to Cure: Mastering Liquid Silicone Rubber for Medical Device Design - Sanner Group","og_url":"https:\/\/www.sanner-group.com\/insights\/blog\/liquid-silicone-rubber-for-medical-device-design\/","og_site_name":"Sanner Group","article_modified_time":"2026-09-01T19:25:39+00:00","og_image":[{"width":2560,"height":1920,"url":"https:\/\/www.sanner-group.com\/wp-content\/uploads\/2024\/01\/Figure-5-scaled-1.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Dur\u00e9e de lecture estim\u00e9e":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.sanner-group.com\/insights\/blog\/liquid-silicone-rubber-for-medical-device-design\/","url":"https:\/\/www.sanner-group.com\/insights\/blog\/liquid-silicone-rubber-for-medical-device-design\/","name":"From Concept to Cure: Mastering Liquid Silicone Rubber for Medical Device Design - Sanner Group","isPartOf":{"@id":"https:\/\/www.sanner-group.com\/fr\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.sanner-group.com\/insights\/blog\/liquid-silicone-rubber-for-medical-device-design\/#primaryimage"},"image":{"@id":"https:\/\/www.sanner-group.com\/insights\/blog\/liquid-silicone-rubber-for-medical-device-design\/#primaryimage"},"thumbnailUrl":"https:\/\/www.sanner-group.com\/wp-content\/uploads\/2024\/01\/Figure-5-scaled-1.jpg","datePublished":"2024-01-23T10:38:01+00:00","dateModified":"2026-09-01T19:25:39+00:00","breadcrumb":{"@id":"https:\/\/www.sanner-group.com\/insights\/blog\/liquid-silicone-rubber-for-medical-device-design\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.sanner-group.com\/insights\/blog\/liquid-silicone-rubber-for-medical-device-design\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.sanner-group.com\/insights\/blog\/liquid-silicone-rubber-for-medical-device-design\/#primaryimage","url":"https:\/\/www.sanner-group.com\/wp-content\/uploads\/2024\/01\/Figure-5-scaled-1.jpg","contentUrl":"https:\/\/www.sanner-group.com\/wp-content\/uploads\/2024\/01\/Figure-5-scaled-1.jpg","width":2560,"height":1920},{"@type":"BreadcrumbList","@id":"https:\/\/www.sanner-group.com\/insights\/blog\/liquid-silicone-rubber-for-medical-device-design\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.sanner-group.com\/fr\/"},{"@type":"ListItem","position":2,"name":"From Concept to Cure: Mastering Liquid Silicone Rubber for Medical Device Design"}]},{"@type":"WebSite","@id":"https:\/\/www.sanner-group.com\/fr\/#website","url":"https:\/\/www.sanner-group.com\/fr\/","name":"Sanner Group","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.sanner-group.com\/fr\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"}]}},"permalink_manager":null,"_links":{"self":[{"href":"https:\/\/www.sanner-group.com\/fr\/wp-json\/wp\/v2\/blog\/5971","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.sanner-group.com\/fr\/wp-json\/wp\/v2\/blog"}],"about":[{"href":"https:\/\/www.sanner-group.com\/fr\/wp-json\/wp\/v2\/types\/blog"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.sanner-group.com\/fr\/wp-json\/wp\/v2\/media\/5432"}],"wp:attachment":[{"href":"https:\/\/www.sanner-group.com\/fr\/wp-json\/wp\/v2\/media?parent=5971"}],"wp:term":[{"taxonomy":"blog_category","embeddable":true,"href":"https:\/\/www.sanner-group.com\/fr\/wp-json\/wp\/v2\/blog_category?post=5971"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}