{"id":1949,"date":"2020-04-03T09:03:36","date_gmt":"2020-04-03T08:03:36","guid":{"rendered":"https:\/\/www.springboard.pro\/?p=1949"},"modified":"2026-09-09T10:42:04","modified_gmt":"2026-09-09T10:42:04","slug":"new-autoinjector","status":"publish","type":"blog","link":"https:\/\/www.sanner-group.com\/insights\/blog\/new-autoinjector\/","title":{"rendered":"Development of a New High-Performance Autoinjector"},"content":{"rendered":"\n<section id=\"armstrong-block-editor-block_416c8000458a13649483d0c1eec0acbd\" class=\"armstrong-block armstrong-block-editor\" >\n    <div class=\"container-fluid\">\n        <div class=\"row\">\n            <div class=\"col-lg-12\">\n                                <p>Prefilled syringes have become the standard format for delivering new biologic drugs. However, they suffer from various issues, such as:<\/p>\n<ol>\n<li>People do not like seeing needles;<\/li>\n<li>There is a risk of contamination and injury via needlesticks;<\/li>\n<li>They can be unsuitable for self-injection by people with hand tremors or dexterity issues from rheumatoid arthritis and suchlike;<\/li>\n<li>The force required to deliver viscous drug formulations through an acceptably thin needle could be too high either for the user, or for the syringe; and<\/li>\n<li>The drug formulation can interact with the silicone lubricant, the steel needle, the adhesive used to attach the needle, or the tungsten used to form the hole for the needle.<\/li>\n<\/ol>\n<p>\u201cStandard\u201d autoinjectors, which are based on a compression spring pushing on the plunger of a prefilled syringe, can solve the first three issues.<\/p>\n<p>The fourth issue is a growing challenge for standard autoinjectors because certain biologics, notably monoclonal antibodies, need to be administered in high concentration for subcutaneous self-administration. This can lead to an increased viscosity of the formulation, which requires greater spring force.\u00a0 Most autoinjector designs hold the plunger rod back away from the plunger when the device is in storage.\u00a0 When the device is triggered, the plunger rod accelerates forwards rapidly until it impacts the plunger and creates shock through the system which can break the syringe.<\/p>\n<p>Another source of impact is where some device designs insert the needle into the patient using the main power spring.\u00a0 This can accelerate the syringe forwards at high speed and cause impact when the syringe is decelerated again.<\/p>\n<p>There are some innovative devices tackling these problems such as the Oval Medical ArQ-Bios which uses a custom primary drug container, or the Consort Medical Syrina AS which uses a liquified gas propellant in place of a spring. Both have their merits but require the pharmaceutical company to support either a non-standard primary drug container or a non-standard power source respectively.<\/p>\n<p>Another way to manage the increasing viscosity is to dilute the formulation back to a more reasonable viscosity and deliver a larger volume injection. Several platform autoinjectors are now available in 2.25 mL syringe formats. However, the change from the 1 mL to the 2.25 mL syringe formats tends to require substantial changes to the device. Changing the CAD models and manufacturing a new set of tools for almost all components entails an increased risk, time delay and cost.\u00a0 Further, in general they cannot support injections greater than 2.25 mL.<\/p>\n<p>There is, therefore, the need for a new autoinjector which:<\/p>\n<ol>\n<li>Avoids the problems associated with prefilled syringes (drug interaction, limited volume, etc.);<\/li>\n<li>Uses a standard primary container that is already used widely for injections;<\/li>\n<li>Uses well-proven componentry (springs, needles, packaging etc.) that is already de-risked and low cost; and<\/li>\n<li>Can deliver higher volumes and\/or viscosity than other low risk autoinjectors.<\/li>\n<\/ol>\n<h2>Why use a cartridge in an autoinjector?<\/h2>\n<p>Pharmaceutical cartridges are used widely to deliver drugs such as insulin, fertility hormones and growth hormone.\u00a0 They differ from the staked-needle syringe in that cartridges have an elastomeric septum seal at one end rather than a needle.\u00a0 Also, cartridges do not have the flange seen on syringes.<\/p>\n<p>The main differences relevant to this discussion are summarized in Table 1.<\/p>\n<table>\n<caption>Table 1: Comparison of syringes and cartridges<\/caption>\n<thead>\n<tr>\n<th>Syringe<\/th>\n<th>Cartridge<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>X\u00a0Limited volume<\/p>\n<p>X\u00a0Fragile flange and shoulder<\/p>\n<p>X\u00a0Tungsten and adhesive around needle<\/p>\n<p>X\u00a0\u201cWet\u201d needle in storage<\/p>\n<p>X\u00a0Sprayed-on silicone oil<\/p>\n<p>\u2714\u00a0Used in early clinical trials<\/td>\n<td>\u2714\u00a0Volume limited only by length<\/p>\n<p>\u2714 No flange, and a strong shoulder<\/p>\n<p>\u2714 No tungsten or adhesive<\/p>\n<p>\u2714 No needle contact in storage<\/p>\n<p>\u2714 Baked-on silicone oil<\/p>\n<p>X\u00a0Not typically used in early clinical trials<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Typically cartridges are not used in early clinical trials.\u00a0 However, they could be used by either fitting an adapter to add a needle and plunger rod, or by using the autoinjector that we will introduce in this article.<\/p>\n<h2>Why pressurize the drug in storage?<\/h2>\n<p>Most spring-powered devices cause an impact when the spring is released.\u00a0 This could be avoided entirely if the spring was already pushing on the plunger, thus pressurizing the drug during storage.\u00a0 The advantages of this approach are:<\/p>\n<ul>\n<li>Impact is avoided, so stronger springs can be used without risk of impact breakage, which in turn means that higher viscosity and\/or larger volumes can be delivered through a given needle diameter.<\/li>\n<li>Air bubbles have been shown to cause degradation of proteins [Christian Dechant, SMi Prefilled Syringes conference 2018-01]. When the drug formulation is pressurized in storage, air tends to dissolve into the solution.\u00a0 In addition, any remaining bubbles are compressed, thus reducing their surface area available for interaction with the drug formulation.<\/li>\n<li>The plunger does not move when ambient air pressure is changed, for example during air freight.<\/li>\n<li>The triggering mechanism can be very simple and completely independent of the rear-end of the autoinjector. The injection can be started by inserting a needle through the cartridge\u2019s septum seal.<\/li>\n<\/ul>\n<p>But could storage under pressure damage the drug? Testing at a pharmaceutical company has shown that there has been no degradation in their drug when stored at maximum pressure over the 3-month time period studied.\u00a0 There is no reason to believe that there will be a different effect with longer duration.\u00a0 In fact, the reduction in bubble number and volume discussed above should reduce degradation.<\/p>\n<h2>The NIS autoinjector<\/h2>\n<p>The \u201cNIS\u201d autoinjector from Midas Pharma (see figure below), created in partnership with Sanner, is a cartridge-based autoinjector wherein the spring is always pushing on the plunger.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"full-width-image\" src=\"https:\/\/www.sanner-group.com\/wp-content\/uploads\/2020\/04\/Figure-1-Photo-of-held-NIS-before-use.png\" sizes=\"auto, (max-width: 1907px) 100vw, 1907px\" srcset=\"https:\/\/www.sanner-group.com\/wp-content\/uploads\/2020\/04\/Figure-1-Photo-of-held-NIS-before-use.png 1907w, https:\/\/www.sanner-group.com\/wp-content\/uploads\/2020\/04\/Figure-1-Photo-of-held-NIS-before-use-258x300.png 258w, https:\/\/www.sanner-group.com\/wp-content\/uploads\/2020\/04\/Figure-1-Photo-of-held-NIS-before-use-880x1024.png 880w, https:\/\/www.sanner-group.com\/wp-content\/uploads\/2020\/04\/Figure-1-Photo-of-held-NIS-before-use-768x894.png 768w, https:\/\/www.sanner-group.com\/wp-content\/uploads\/2020\/04\/Figure-1-Photo-of-held-NIS-before-use-1319x1536.png 1319w, https:\/\/www.sanner-group.com\/wp-content\/uploads\/2020\/04\/Figure-1-Photo-of-held-NIS-before-use-1759x2048.png 1759w\" alt=\"NIS autoinjector in use\" width=\"1907\" height=\"2220\" \/><\/p>\n<p>The simplicity of the NIS design (see figure below) means that:<\/p>\n<ol>\n<li>A 1.5 mL or 3 mL cartridge can be used with only minor changes. For example, the same tool could be used for the main body, which is unique amongst autoinjectors.<\/li>\n<li>For a given cartridge diameter, a change in drug volume or viscosity needs only a change in the spring and plunger rod length.<\/li>\n<\/ol>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"full-width-image\" src=\"https:\/\/www.sanner-group.com\/wp-content\/uploads\/2020\/04\/Figure-2-NIS-section-defeatured.png\" sizes=\"auto, (max-width: 880px) 100vw, 880px\" srcset=\"https:\/\/www.sanner-group.com\/wp-content\/uploads\/2020\/04\/Figure-2-NIS-section-defeatured.png 880w, https:\/\/www.sanner-group.com\/wp-content\/uploads\/2020\/04\/Figure-2-NIS-section-defeatured-300x42.png 300w, https:\/\/www.sanner-group.com\/wp-content\/uploads\/2020\/04\/Figure-2-NIS-section-defeatured-768x106.png 768w\" alt=\"NIS section defeatured\" width=\"880\" height=\"122\" \/><\/p>\n<p>The design is so simple that it is possible to remove even the step of removing a cap, which would make the NIS autoinjector the first \u201cone step\u201d autoinjector on the market (Figure 3).<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"full-width-image\" src=\"https:\/\/www.sanner-group.com\/wp-content\/uploads\/2020\/04\/Figure-3-NIS-use-steps.png\" sizes=\"auto, (max-width: 1312px) 100vw, 1312px\" srcset=\"https:\/\/www.sanner-group.com\/wp-content\/uploads\/2020\/04\/Figure-3-NIS-use-steps.png 1312w, https:\/\/www.sanner-group.com\/wp-content\/uploads\/2020\/04\/Figure-3-NIS-use-steps-300x192.png 300w, https:\/\/www.sanner-group.com\/wp-content\/uploads\/2020\/04\/Figure-3-NIS-use-steps-1024x655.png 1024w, https:\/\/www.sanner-group.com\/wp-content\/uploads\/2020\/04\/Figure-3-NIS-use-steps-768x491.png 768w\" alt=\"NIS use steps\" width=\"1312\" height=\"839\" \/><\/p>\n<h2>How can we predict autoinjector performance?<\/h2>\n<p>Our primary considerations are that the autoinjector should:<\/p>\n<ol>\n<li>Be safe, which means, for example, a low chance of breakage or underdose.<\/li>\n<li>Deliver the drug through a thin needle in a reasonable time.<\/li>\n<\/ol>\n<p>In order to answer the second point, we would like to know the maximum viscosity each autoinjector design can deliver through a given needle gauge in the maximum allowable injection time limit.<\/p>\n<p>The injection time is dominated by the drug formulation being pushed through the needle. Flow through the needle is governed by the Hagen-Poiseuille equation:<\/p>\n<p>$$Q = \\frac{\\pi \\Delta P d^4}{128 \\mu L}$$<\/p>\n<p>Rearranging to calculate injection time gives:<\/p>\n<p>$$t = \\frac{32 \\mu L V D^2}{F d^4}$$<\/p>\n<p>Where Q is flow rate, \u03c0 = 3.141, \u0394P is the pressure drop, d is the needle inner diameter, \u03bc is the dynamic viscosity, L is the needle length, t is the injection time, V is the drug volume, D is the syringe inner diameter, F is the force on the drug (which is spring force minus any friction).<\/p>\n<p>The figure below shows the correlation between measured injection time and predicted injection time for an example autoinjector filled with calibrated 50 cP silicone oil.\u00a0 The difference between measured and predicted injection time is not more than 1.5% so the model is good enough for our purposes.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"full-width-image\" src=\"https:\/\/www.sanner-group.com\/wp-content\/uploads\/2020\/04\/Figure-4-actual-versus-predicted-injection-time.png\" sizes=\"auto, (max-width: 1905px) 100vw, 1905px\" srcset=\"https:\/\/www.sanner-group.com\/wp-content\/uploads\/2020\/04\/Figure-4-actual-versus-predicted-injection-time.png 1905w, https:\/\/www.sanner-group.com\/wp-content\/uploads\/2020\/04\/Figure-4-actual-versus-predicted-injection-time-300x231.png 300w, https:\/\/www.sanner-group.com\/wp-content\/uploads\/2020\/04\/Figure-4-actual-versus-predicted-injection-time-1024x789.png 1024w, https:\/\/www.sanner-group.com\/wp-content\/uploads\/2020\/04\/Figure-4-actual-versus-predicted-injection-time-768x592.png 768w, https:\/\/www.sanner-group.com\/wp-content\/uploads\/2020\/04\/Figure-4-actual-versus-predicted-injection-time-1536x1184.png 1536w\" alt=\"Actual versus predicted injection time\" width=\"1905\" height=\"1468\" \/><\/p>\n<h2>How does the NIS autoinjector compare with competitors?<\/h2>\n<p>We could use the equation above to calculate the maximum viscosity which each autoinjector can inject in a given time through a given needle diameter, but that would assume that every parameter was at its mean value and would take no account of variation.<\/p>\n<p>But we want all injections to be under a given time limit, so we care about the <em>slowest<\/em> injections, not the mean. We need to calculate the <em>distribution<\/em> of injection times.<\/p>\n<p>We could use algebraic manipulation, but this is challenging and would become very challenging if any of the input distributions were not Gaussian. Instead, we can use a Monte Carlo simulation.\u00a0 For those who are not familiar with this method, the steps are:<\/p>\n<ol>\n<li>Model the distribution of each input to the equation (drug volume, needle diameter, etc.)<\/li>\n<li>Take one sample at random from each input distribution.<\/li>\n<li>Calculate one output value by putting the sample input values through our equation.<\/li>\n<li>Repeat steps 2 and 3 until we have a suitably large number of output samples to represent the output distribution.<\/li>\n<\/ol>\n<p>The validity of the Monte Carlo method depends on several factors being true:<\/p>\n<ol>\n<li>The inputs must be independent. For example, the needle diameter should not correlate with the needle length.<\/li>\n<li>The inputs should be representative. We have made our best efforts to use industry-wide tolerances and international standards.<\/li>\n<\/ol>\n<p>Spring force:<\/p>\n<ul>\n<li>Each device platform has limited space for the spring.<\/li>\n<li>We calculated the strongest spring we thought could be designed into the space allowed.<\/li>\n<li>We used the industry standard tolerance of \u00b1 10% on spring force.<\/li>\n<\/ul>\n<p>Device friction and Plunger-Cartridge friction:<\/p>\n<ul>\n<li>Nominal friction was measured from device samples.<\/li>\n<li>Tolerance was estimated at \u00b1 70% (which approximates measurements from similar device developments).<\/li>\n<\/ul>\n<p>Container diameter:<\/p>\n<ul>\n<li>Nominal diameter was measured from device samples.<\/li>\n<li>We matched the diameter to the nearest standard glass tube and used \u00b1 0.1 mm from ISO 13926-1:2004.<\/li>\n<\/ul>\n<p>Needle length:<\/p>\n<ul>\n<li>Nominal was measured from device samples.<\/li>\n<li>Tolerance of \u00b1 1 mm used because ISO 7864:2016 specifies maximum +1 mm and -2 mm.<\/li>\n<\/ul>\n<p>We used the Monte Carlo method to calculate the maximum viscosity that could be injected by the NIS autoinjector and 3 competitors for various needle gauges with no more than 1% of injections taking more than 15 seconds.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"full-width-image\" src=\"https:\/\/www.sanner-group.com\/wp-content\/uploads\/2020\/04\/Figure-5-viscosity-versus-needle-gauge.png\" sizes=\"auto, (max-width: 1370px) 100vw, 1370px\" srcset=\"https:\/\/www.sanner-group.com\/wp-content\/uploads\/2020\/04\/Figure-5-viscosity-versus-needle-gauge.png 1370w, https:\/\/www.sanner-group.com\/wp-content\/uploads\/2020\/04\/Figure-5-viscosity-versus-needle-gauge-300x236.png 300w, https:\/\/www.sanner-group.com\/wp-content\/uploads\/2020\/04\/Figure-5-viscosity-versus-needle-gauge-1024x804.png 1024w, https:\/\/www.sanner-group.com\/wp-content\/uploads\/2020\/04\/Figure-5-viscosity-versus-needle-gauge-768x603.png 768w\" alt=\"Viscosity versus needle gauge\" width=\"1370\" height=\"1076\" \/><\/p>\n<p>The results above show that the NIS autoinjector could inject significantly higher viscosity drugs than competitor devices. Alternatively, a similar viscosity could be delivered by the NIS through a smaller needle than competitors.<\/p>\n<p>Competitor devices would probably have unacceptable risks such as plastic creep or glass impact if they used the maximum force spring that could fit.<\/p>\n<h2>Summary<\/h2>\n<p>There are demonstrable advantages to using a cartridge over a syringe in an autoinjector, as described in Table 1.<\/p>\n<p>Furthermore, pressurizing the drug in storage can eliminate impacts and reduce drug degradation. Elimination of impacts means that the autoinjector could be designed to deliver higher viscosities and\/or volumes than competitors that are on the market.<\/p>\n<p>The NIS autoinjector embodies these ideas in a simple and low-risk design.<\/p>\n<p>Written by Tom Oakley<\/p>\n            <\/div>\n        <\/div>\n    <\/div>\n<\/section>","protected":false},"featured_media":1957,"template":"","blog_category":[75,118],"class_list":["post-1949","blog","type-blog","status-publish","has-post-thumbnail","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.6 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Development of a New High-Performance Autoinjector - Sanner Group<\/title>\n<meta name=\"description\" content=\"Delivering biologics can be complicated. Discover how Sanner designed and developed an high-performance autoinjector to help patients.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.sanner-group.com\/zh-hans\/insights\/blog\/new-autoinjector\/\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Development of a New High-Performance Autoinjector - Sanner Group\" \/>\n<meta property=\"og:description\" content=\"Delivering biologics can be complicated. Discover how Sanner designed and developed an high-performance autoinjector to help patients.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.sanner-group.com\/insights\/blog\/new-autoinjector\/\" \/>\n<meta property=\"og:site_name\" content=\"Sanner Group\" \/>\n<meta property=\"article:modified_time\" content=\"2026-09-09T10:42:04+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.sanner-group.com\/wp-content\/uploads\/2020\/04\/Figure-3-NIS-use-steps.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1312\" \/>\n\t<meta property=\"og:image:height\" content=\"839\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.sanner-group.com\\\/insights\\\/blog\\\/new-autoinjector\\\/\",\"url\":\"https:\\\/\\\/www.sanner-group.com\\\/insights\\\/blog\\\/new-autoinjector\\\/\",\"name\":\"Development of a New High-Performance Autoinjector - Sanner Group\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.sanner-group.com\\\/zh-hans\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.sanner-group.com\\\/insights\\\/blog\\\/new-autoinjector\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.sanner-group.com\\\/insights\\\/blog\\\/new-autoinjector\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.sanner-group.com\\\/wp-content\\\/uploads\\\/2020\\\/04\\\/Figure-3-NIS-use-steps.png\",\"datePublished\":\"2020-04-03T08:03:36+00:00\",\"dateModified\":\"2026-09-09T10:42:04+00:00\",\"description\":\"Delivering biologics can be complicated. Discover how Sanner designed and developed an high-performance autoinjector to help patients.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.sanner-group.com\\\/insights\\\/blog\\\/new-autoinjector\\\/#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.sanner-group.com\\\/insights\\\/blog\\\/new-autoinjector\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\\\/\\\/www.sanner-group.com\\\/insights\\\/blog\\\/new-autoinjector\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.sanner-group.com\\\/wp-content\\\/uploads\\\/2020\\\/04\\\/Figure-3-NIS-use-steps.png\",\"contentUrl\":\"https:\\\/\\\/www.sanner-group.com\\\/wp-content\\\/uploads\\\/2020\\\/04\\\/Figure-3-NIS-use-steps.png\",\"width\":1312,\"height\":839,\"caption\":\"NIS use steps\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.sanner-group.com\\\/insights\\\/blog\\\/new-autoinjector\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.sanner-group.com\\\/zh-hans\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Development of a New High-Performance Autoinjector\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.sanner-group.com\\\/zh-hans\\\/#website\",\"url\":\"https:\\\/\\\/www.sanner-group.com\\\/zh-hans\\\/\",\"name\":\"Sanner Group\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.sanner-group.com\\\/zh-hans\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Development of a New High-Performance Autoinjector - Sanner Group","description":"Delivering biologics can be complicated. Discover how Sanner designed and developed an high-performance autoinjector to help patients.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.sanner-group.com\/zh-hans\/insights\/blog\/new-autoinjector\/","og_locale":"zh_CN","og_type":"article","og_title":"Development of a New High-Performance Autoinjector - Sanner Group","og_description":"Delivering biologics can be complicated. Discover how Sanner designed and developed an high-performance autoinjector to help patients.","og_url":"https:\/\/www.sanner-group.com\/insights\/blog\/new-autoinjector\/","og_site_name":"Sanner Group","article_modified_time":"2026-09-09T10:42:04+00:00","og_image":[{"width":1312,"height":839,"url":"https:\/\/www.sanner-group.com\/wp-content\/uploads\/2020\/04\/Figure-3-NIS-use-steps.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"1 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.sanner-group.com\/insights\/blog\/new-autoinjector\/","url":"https:\/\/www.sanner-group.com\/insights\/blog\/new-autoinjector\/","name":"Development of a New High-Performance Autoinjector - Sanner Group","isPartOf":{"@id":"https:\/\/www.sanner-group.com\/zh-hans\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.sanner-group.com\/insights\/blog\/new-autoinjector\/#primaryimage"},"image":{"@id":"https:\/\/www.sanner-group.com\/insights\/blog\/new-autoinjector\/#primaryimage"},"thumbnailUrl":"https:\/\/www.sanner-group.com\/wp-content\/uploads\/2020\/04\/Figure-3-NIS-use-steps.png","datePublished":"2020-04-03T08:03:36+00:00","dateModified":"2026-09-09T10:42:04+00:00","description":"Delivering biologics can be complicated. Discover how Sanner designed and developed an high-performance autoinjector to help patients.","breadcrumb":{"@id":"https:\/\/www.sanner-group.com\/insights\/blog\/new-autoinjector\/#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.sanner-group.com\/insights\/blog\/new-autoinjector\/"]}]},{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/www.sanner-group.com\/insights\/blog\/new-autoinjector\/#primaryimage","url":"https:\/\/www.sanner-group.com\/wp-content\/uploads\/2020\/04\/Figure-3-NIS-use-steps.png","contentUrl":"https:\/\/www.sanner-group.com\/wp-content\/uploads\/2020\/04\/Figure-3-NIS-use-steps.png","width":1312,"height":839,"caption":"NIS use steps"},{"@type":"BreadcrumbList","@id":"https:\/\/www.sanner-group.com\/insights\/blog\/new-autoinjector\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.sanner-group.com\/zh-hans\/"},{"@type":"ListItem","position":2,"name":"Development of a New High-Performance Autoinjector"}]},{"@type":"WebSite","@id":"https:\/\/www.sanner-group.com\/zh-hans\/#website","url":"https:\/\/www.sanner-group.com\/zh-hans\/","name":"Sanner Group","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.sanner-group.com\/zh-hans\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"}]}},"permalink_manager":null,"_links":{"self":[{"href":"https:\/\/www.sanner-group.com\/zh-hans\/wp-json\/wp\/v2\/blog\/1949","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.sanner-group.com\/zh-hans\/wp-json\/wp\/v2\/blog"}],"about":[{"href":"https:\/\/www.sanner-group.com\/zh-hans\/wp-json\/wp\/v2\/types\/blog"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.sanner-group.com\/zh-hans\/wp-json\/wp\/v2\/media\/1957"}],"wp:attachment":[{"href":"https:\/\/www.sanner-group.com\/zh-hans\/wp-json\/wp\/v2\/media?parent=1949"}],"wp:term":[{"taxonomy":"blog_category","embeddable":true,"href":"https:\/\/www.sanner-group.com\/zh-hans\/wp-json\/wp\/v2\/blog_category?post=1949"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}